BSQDR - BATTERY WET, FILLED WITH ACID

Product Identification

Product ID:BATTERY WET, FILLED WITH ACID
MSDS Date:04/06/1993
FSC:6140
NIIN:01-210-1964
MSDS Number: BSQDR

Responsible Party
EAST PENN MANUFACTURING CO. INC.
DEKA ROAD
LYON STATION, PA 19536
US

Emergency Phone: 215 682-6361

Info Phone: 215 682-6361

Cage: DO231

Contractor
EAST PENN MFG CO INC
LYON STATION, PA 19536 US

Telephone: 610-682-6361

Cage: 04055

Ingredients

LEAD, INORGANIC LEAD (SUSPECTED HUMAN CARCINOGEN BY IARC,

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 43-70%

ACGIH TLV: 0.15 MG/CUM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 0-4%

OSHA PEL 0.5 MG/CUM

ACGIH TLV: 0.5 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SULFURIC ACID IC=INTENDED CHANGES

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 20-44%

OSHA PEL 1 MG/CUM

ACGIH TLV: 1 MG/CUM=IC

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CONTACT MAY CAUSE EYE, NOSE, THROAT
IRRITATION; POSSIBLE SEVERE SKIN BURNS, EROSION OF TEETH.
INHALATION: RESPIRATORY DIFFICULTY; INFLAMMATION OF NOSE, THROAT, &
BRONCHIAL TUBES.
Explanation of Carcinogenicity:SEE INGREDIENTS
Medical Cond Aggravated by Exposure:PULMONARY EDEMA, BRONCHITIS,
EMPHYSEMA, DENTAL EROSION, TRACHEOBRONCHITIS.

First Aid

First Aid:SKIN: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. REMOVE CONTAMINATED CLOTHING. INGESTION: GIVE LARGE
AMOUNTS OF WATER, DO NOT INDUCE VOMITING. OBTAIN MEDICAL ATTENTION
IN ALL CASES.

Fire Fighting

Flash Point:NON-FLAMMABLE
Lower Limits:4% SEE SUPP
Upper Limits:74% SEE SUPP
Extinguishing Media:CLASS A,B,C EXTINGUISHER; CO2, HALON
Fire Fighting Procedures:COOL EXTERIOR OF BATTERY TO PREVENT RUPTURE.
WEAR SCBA & PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:HYDROGEN GAS IS PRODUCED, WHICH MAY
EXPLODE IF IGNITED. ACID MIST & VAPORS IN A FIRE SITUATION ARE
CORROSIVE.

Accidental Release

Spill Release Procedures:DILUTE W/5-6 VOLUMES OF WATER & GRADUALLY
NEUTRALIZE. WEAR NIOSH APPROVED POSITIVE PRESSURE SCBA WHEN
EXPOSURE LEVEL UNKNOWN.
Neutralizing Agent:SODIUM BICARBONATE, SODA ASH, LIME

Handling

Handling and Storage Precautions:STORE AWAY FROM REACTIVE MATERIALS.
KEEP NEUTRALIZERS/SAND IN SAME GENERAL AREA. IF BATTERY CASE IS
BROKEN, AVOID CONTACT W/INTERNAL COMPONENTS.

Exposure Controls

Respiratory Protection:ACID GAS RESPIRATOR WHEN PEL IS EXCEEDED OR
EMPLOYEE EXPERIENCES RESPIRATORY IRRITATION.
Ventilation:ENCLOSED AREA: LOCAL EXHAUST PREFERRED; MECHANICAL
ACCEPTABLE @ 1-4 AIR EXCHANGES/HOUR. USE EXPLOSION-PROOF EQUIPMENT.
Protective Gloves:ACID PROOF (RUBBER)
Eye Protection:REQUIRED
Other Protective Equipment:ACID RESISTANT APRON, BOOTS, PROTECTIVE
CLOTHING. EYEWASH & SHOWER STATIONS SHOULD BE MADE AVAILABLE.
Work Hygienic Practices:GOOD PERSONAL HYGIENE/WORK PRACTICES ARE
MANDATORY.
Supplemental Safety and Health
LEL & UEL INFORMATION IS FOR HYDROGEN GAS.

Chemical Properties

HCC:C1
Boiling Pt:B.P. Text:235 F
Decomp Temp:Decomp Text:322-770F
Vapor Pres:13
Spec Gravity:1.220-1.325
Evaporation Rate & Reference:(BU AC=1): <1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, ODORLESS, COLORLESS

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS (SUCH AS HOT NITRIC ACID)
Stability Condition to Avoid:TEMPERATURES > 322-770F & OTHER IGNITION
SOURCES
Hazardous Decomposition Products:HYDROGEN GAS, CO, CO2, & ACID
MIST/VAPORS

Disposal

Waste Disposal Methods:LEAD-ACID BATTERIES ARE COMPLETELY RECYCLABLE.
TO RETURN BATTERIES TO EAST PENN, CALL (215) 682-6361. UN2794.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.